Station, Object, Action, New Serial, Old Serial#, StartDate,EndDate,TaskName,Notes1,Notes2,Notes3 "Caseta" "Rain Gauge" "Replaced" "" "" 27/06/2012 27/06/2012 "Replace plastic rain gauge" "Replace plastic rainfall catcher(All wether raingauge).RR & RT" "" "" "Crane Top" "Datalogger" "Replaced" "50656" "16395" 01/01/2016 01/01/2016 "Replaced data-logger - station hit by lightning" "" "" "" "Crane Top" "Anemometer" "Replaced" "" "" 01/02/2007 01/02/2007 "Replace Anemometer" "" "" "" "Crane Top" "Anemometer" "Repaired" "" "" 01/07/1998 01/07/1998 "Reposition Anemometer" "Additional PAR sensor installed. Connected to LiCor datalogger" "" "" "Crane Top" "Anemometer" "Repaired" "" "" 02/06/1998 02/06/1998 "Reconnect Anemometer cable" "Anemometer accidentally moved sometime around June 30" "" "" "Crane Top" "Datalogger" "Observation" "" "" 02/07/2010 02/07/2010 "Raw data error" "On July 2, 2010 by inspecting the solar radiation data from Sherman it was found that between 2007/07/27 03:30 and 2007/10/04 02:15 the logger time was wrong by about 9h :15 min.This can easily be seen from the solar radiation data for this period. Marc" "h 15, 2011 - The aforementioned problem with the Sherman timestamp was fixed on the raw data files located on P:\Mesp\Phys_mon\RAW_DATA sds" "" "Crane Top" "Anemometer" "Observation" "" "" 03/03/2000 05/05/2000 "No wind speed data during this period" "Propeller fell off" "" "" "Crane Top" "T&H sensor" "Chip Replaced" "" "" 03/08/2011 03/08/2011 "Change T&H sensor chip" "August 3, 2011 The T&RH chip for the CS215 sensor was replaced. The old chip was giving large negative values, e.g -100 for temperature. Logger stopped at 10:35 Logger restarted at 10:50" "" "" "Crane Top" "PAR sensor" "Replaced" "" "" 03/12/1999 03/12/1999 "Replace both PAR sensors" "" "" "" "Crane Top" "T&H sensor" "Replaced" "" "" 03/12/1999 03/12/1999 "Replace Temp/Hum sensor" "" "" "" "Crane Top" "Anemometer" "Replaced" "101115" "40007" 04/02/2015 12/02/2015 "Anemometer nose bearings bad - replaced instrument" "- On February 4th, 2015 on a routine data collection visit to the Sherman crane it was found that the nose-cone bearings were damaged. February 12th, 2015 Logger shutdown at 10:35 am -Removed 05103 RM Young Anemometer SN:40007 -Installed 05103 RM Young" "Anemometer SN:101115 Logger power-up at 11:40 am" "" "Crane Top" "T&H sensor" "Replaced" "E3990" "8809-7" 04/05/2010 04/05/2010 "Replace T&H sensor with new model" "May 04, 2010 - Overall maintenance of the Sherman Crane Station Replaced Temperature and RH sensor -Installed CS215 T&RH sensor, S/N:E3990 -Removed CS500 T&RH, S/N:8809-7 (AA2330042)" "" "" "Crane Top" "Pyranometer" "Installed" "63939" "" 04/05/2010 04/05/2010 "Install Pyranometer" "May 04, 2010 - Overall maintenance of the Sherman Crane Station Replaced SR sensor and installed and additonal sensor -Installed LI200S SR sensor, S/N:PY63939 -Installed LI200X SR sensor, S/N:PY10373 -Remove LI200S SR sensor, S/N:PY61707" "" "" "Crane Top" "Pyranometer" "Replaced" "10373" "61707" 04/05/2010 04/05/2010 "Replace Pyranometer" "May 04, 2010 - Overall maintenance of the Sherman Crane Station Replaced SR sensor and installed and additonal sensor -Installed LI200X SR sensor, S/N:PY10373 -Remove LI200S SR sensor, S/N:PY61707" "" "" "Crane Top" "Anemometer" "Replaced" "33418" "5946" 04/05/2010 04/05/2010 "Replace Anemometer" "May 04, 2010 - Overall maintenance of the Sherman Crane Station Replaced anemometer -Installed 05103 anemometer, S/N:33418 -Removed 05103 anemometer, S/N:5946" "" "" "Crane Top" "Datalogger" "Reprogrammed" "" "" 04/05/2010 04/05/2010 "Load new program into datalogger" "May 04, 2010 - Overall maintenance of the Sherman Crane Station Loaded new program -Loaded program sherman_crane20100405kk.dld -Removed program Sherman_crane20090212kk.dld" "" "" "Crane Top" "" "Observation" "" "" 04/05/2010 04/05/2010 "Orientation of tower measured" "May 04, 2010 - Overall maintenance of the Sherman Crane Station From readings taken with a Garmin GPS and a magnetic compass (at 50m from the crane) it looks like the side of the crane's mast that faces Manzanillo bay is 20 Degrees from North due East." "" "" "Crane Top" "Anemometer" "Replaced" "" "" 05/05/2000 05/05/2000 "Replace Anemometer" "Tipping bucket moved by workers. No good data between Dec 23, 2001 and June 20, 2002. Data replaced in database by data from the ACP Gatun West site" "" "" "Crane Top" "PAR sensor" "Replaced" "" "" 05/07/2007 05/07/2007 "Replace PAR sensor" "" "" "" "Crane Top" "Tipping Bucket" "Repaired" "" "" 05/08/2010 05/08/2010 "Repair broken Tipping Bucket cable" "August 5th, 2010 Logger disconnected between 11:30 and 13:10. The Tipping Bucket cable was found to be broken on August 5th, 2010. The cable got damaged sometime between July 16 and July 29. On August 5th the Tipping bucket cable was fixed-up. Failed" "attempt to replace the support U-bolts - Tipping bucket had to be attached with cables ties to the support bars, i.e. cables ties to attached PVC support to the metal bars of the crane's counterbalance concrete structure" "" "Crane Top" "Tipping Bucket" "Observation" "" "" 05/08/2010 11/08/2010 "Tipping Bucket tilted 45 degrees" "August 5th, 2010 Logger disconnected between 11:30 and 13:10. The Tipping Bucket cable was found to be broken on August 5th, 2010. The cable got damaged sometime between July 16 and July 29. On August 5th the Tipping bucket cable was fixed-up. Failed" "attempt to replace the support U-bolts - Tipping bucket had to be attached with cables ties to the support bars, i.e. cables ties to attached PVC support to the metal bars of the crane's counterbalance concrete structure" "" "Crane Top" "Tipping Bucket" "Replaced" "06-287" "2012-205" 05/08/2015 05/08/2015 "Replace Tipping bucket" "August 5th, 2015 Work done between 8:20am and 12:00. No pwer cycling of the logger -Loose tipping bucket cable - most likely resulting from the June 19, 2015 installation of the pyranometers -It can be assumed that we lost TB rainfall data between 2015/0" "6/19 and 2015/08/05 -Removed TB3 SN:2012-205 -Installed TB4: SN:06-287" "" "Crane Top" "Pyranometer" "Repaired" "" "" 05/12/2013 05/12/2013 "Replace support for SR sensor front" "Dec. 5, 2013 Installed new supports for the solar radiation (LI200S) sensors New supports are easier to level" "" "" "Crane Top" "Pyranometer" "Repaired" "" "" 05/12/2013 05/12/2013 "Replace support for SR sensor back" "Dec. 5, 2013 Installed new supports for the solar radiation (LI200S) sensors New supports are easier to level" "" "" "Crane Top" "Tipping Bucket" "Observation" "" "" 06/01/2011 08/01/2011 "Tipping bucket disconnected" "Tipping bucket reconnected at 9:30hr - raining heavily at this time" "" "" "Crane Top" "Tipping Bucket" "Repaired" "" "" 06/01/2011 08/01/2011 "Reconnect Tipping bucket" "" "" "" "Crane Top" "Tipping Bucket" "Replaced" "2012-205" "06-287" 06/04/2016 06/04/2016 "Replaced Tipping Bucket" "" "" "" "Crane Top" "Tipping Bucket" "Repaired" "" "" 06/05/2003 06/05/2003 "Repair Tipping bucket" "" "" "" "Crane Top" "PAR sensor" "Replaced" "" "" 06/07/2007 06/07/2007 "Replace PAR sensor" "" "" "" "Crane Top" "PAR sensor" "Observation" "" "" 07/06/2007 05/07/2007 "Both PAR sensors damaged" "" "" "" "Crane Top" "T&H sensor" "Replaced" "E4333" "E3990" 07/09/2011 07/09/2011 "Replace T&RH" "September 7, 2011 On 2011/09/07 the following maintenance was performed: Logger shutdown at 10:20 am -Installed a T&RH with a chip. Sensor CS215 S/N: E4333 -Removed T&RH CS215 S/N:E3990 - The sensor was giving bad values (-100) although it had" " a new chip Logger powered-up at 12:12" "" "Crane Top" "Anemometer" "Replaced" "19852" "33418" 07/09/2011 07/09/2011 "Replace Anemometer" "September 7, 2011 Logger shutdown at 10:20 am -Installed a calibrated Anemometer RM Young 05103 S/N: 19852 -Removed damaged anemometer RM Young 05103 S/N:33418 - The propeler bearings were damaged. Logger powered-up at 12:12" "" "" "Crane Top" "T&H sensor" "Observation" "" "" 07/09/2011 07/09/2011 "T&RH sensor failed after the August 3, 2011 maintenance." "The T&RH sensor failed after the August 3, 2011 maintenance." "" "" "Crane Top" "Anemometer" "Observation" "" "" 07/09/2011 07/09/2011 "Anemometer failed around 2011-07-28 5:30 am" "September 7, 2011 The Anemometer failed at the end of July 2001 - it started to give bad values around 2011-07-28 5:30 am" "" "" "Crane Top" "Pyranometer" "Replaced" "73904" "63939" 08/05/2012 08/05/2012 "Replace Pyranometer front" "May 8th, 2012 Replaced SR sensors Installed new sensors PY73904(F) Removed sensors PY63939(F)" "" "" "Crane Top" "Pyranometer" "Replaced" "73905" "63943" 08/05/2012 08/05/2012 "Replace Pyranometer back" "May 8th, 2012 Replaced SR sensors Installed new sensors PY73905(B) Removed sensors PY63943(B)" "" "" "Crane Top" "Tipping Bucket" "Calibrated" "" "" 08/05/2012 08/05/2012 "Calibrate Tipping bucket" "May 8th, 2012 Calibrated TB Poured 628cc of water and got 20mm of rain" "" "" "Crane Top" "PAR sensor" "Installed" "" "" 09/02/1999 09/02/1999 "Install PAR sensor" "Additional PAR sensor installed. Connected to LiCor datalogger" "" "" "Crane Top" "PAR sensor" "Installed" "" "" 09/02/1999 09/02/1999 "Install PAR sensor" "" "" "" "Crane Top" "Anemometer" "Calibrated" "" "" 09/02/1999 09/02/1999 "Calibrate Anemometer direction" "Direction adjusted by +30 degrees. Data as far back as June 30, 1998 needs to be adjusted" "" "" "Crane Top" "Anemometer" "Repaired" "" "" 09/02/2011 09/02/2011 "Install Anemometer Arm" "Feb. 9, 2011 -Datalogger disconnected between 11:01 and 14:00 -Installed a new support arm for the anemometer -The orientation of the anemometer base was kept as before - the wiring box faces a southwest direction. And when the anemometer is aligned wit" "h the wiring box it gives a reading of 36 degrees. This is becuase the datalogger program accounts for a 30 deg ree diffrence betwen North and the alignment of anemometer 0 direction, i.e. the wiring box alignment is 30 degrees ahead of north." "" "Crane Top" "Pyranometer" "Observation" "" "" 09/02/2011 09/02/2011 "Pyranometer reading low" "Feb. 9, 2011 SR B pyranometer reading low - needs to be replaced ASAP. The B pyranometer was a recalibrated instrument. The program should no longer use recalibrated pyranometers." "" "" "Crane Top" "Tipping Bucket" "Calibrated" "" "" 09/02/2011 09/02/2011 "Calibrate Tipping bucket" "Feb. 9, 2011 -Datalogger disconnected between 11:01 and 14:00 -Calibrated the tipping bucket - 314ml of water poured in 15min were measured by the TB as 10.414 mm of rain. TB ok and the extra rain could have been from water remaining on TB mechanism fr" "om previous rain or human error on measuring the water." "" "Crane Top" "Anemometer" "Observation" "" "" 09/10/2003 11/11/2003 "No Anemometer data during this period" "Wind speed fixed, but direction still not working" "" "" "Crane Top" "Anemometer" "Observation" "" "" 09/10/2003 02/01/2007 "No wind direction data during this period" "Cable broken. Last known precipitation on July 28" "" "" "Crane Top" "Anemometer" "Observation" "" "" 10/11/1999 03/12/1999 "No wind speed data during this period" "" "" "" "Crane Top" "Anemometer" "Repaired" "" "" 10/11/1999 03/12/1999 "Fix Anemometer - loose connection" "Disconnected wire beginning Nov 10 @ 14:15hr" "" "" "Crane Top" "Pyranometer" "Modified" "" "" 11/01/2012 11/01/2012 "Level Pyranometers" "" "" "" "Crane Top" "Tipping Bucket" "Repaired" "" "" 11/08/2010 11/08/2010 "Fix tipping bucket so it will not tilt" "August 11th, 2010 Replaced the support U-Bolts of the Tipping Bucket. The temporary solution of using cable ties to attached the Tipping Bucket did not work - the TB was found leaning to one side (45 degrees) on August 11th. No good rain data between Jul" "y 16 (approximatelly) and August 11th. On August 11th the U-Bolts of the tipping bucket were sucessfuly replaced and the TB was back into normal operation." "" "Crane Top" "T&H sensor" "Replaced" "" "" 11/11/2003 11/11/2003 "Replace Temp/Hum sensor with new model" "Replace HMP35 with HMP45C" "" "" "Crane Top" "Anemometer" "Repaired" "" "" 11/11/2003 11/11/2003 "Repair Anemometer" "" "" "" "Crane Top" "Battery" "Battery Replaced" "" "" 11/11/2015 11/11/2015 "Replace battery" "November 11, 2015 Logger power-down @ 12:10 pm -Installed 9Ah battery -Removed 7Ah battery Logger power-up @ 12:11 pm" "" "" "Crane Top" "Anemometer" "Observation" "" "" 12/01/2000 26/01/2000 "No wind speed data during this period" "Disconnected wire beginning Nov 10 @ 14:15hr" "" "" "Crane Top" "PAR sensor" "Replaced" "" "" 12/05/2005 12/05/2005 "Replace PAR sensor #1" "Bearings need replacing again" "" "" "Crane Top" "Anemometer" "Repaired" "" "" 12/05/2005 12/05/2005 "Replace propeller bearings" "" "" "" "Crane Top" "Anemometer" "Observation" "" "" 12/05/2005 12/05/2005 "Propeller not working - bearings rusted" "" "" "" "Crane Top" "Tipping Bucket" "Repaired" "" "" 12/08/2004 12/08/2004 "Repair Tipping bucket cable" "Cable broken. Last known precipitation on July 28" "" "" "Crane Top" "Tipping Bucket" "Cleaned" "" "" 12/10/2012 12/10/2012 "Clean Tipping bucket" "Install Forestry Service Raingauge" "" "" "Crane Top" "T&H sensor" "Replaced" "K4930027" "E7220" 13/07/2016 13/07/2016 "Replaced T&RH sensor" "" "" "" "Crane Top" "Pyranometer" "Replaced" "151575" "86864" 13/07/2016 13/07/2016 "Replaced SR Back sensor" "" "" "" "Crane Top" "Anemometer" "Moved" "" "" 14/01/1998 14/01/1998 "Move Anemometer" "Anemometer moved ~50cm farther out on support pole" "" "" "Crane Top" "PAR sensor" "Installed" "" "" 14/01/1998 14/01/1998 "Install PAR sensor" "Anemometer moved ~50cm farther out on support pole" "" "" "Crane Top" "Anemometer" "Installed" "" "" 14/01/1998 14/01/1998 "Install Leaf-wetness sensor" "Anemometer moved ~50cm farther out on support pole" "" "" "Crane Top" "T&H sensor" "Replaced" "E7220" "E4058" 14/10/2015 14/10/2015 "Replace T&RH sensor" "October 14, 2015 -Removed CS215 T&RH sensor SN:E4058 -Installed CS215 T&RH sensor SN:E7220" "" "" "Crane Top" "Tipping Bucket" "Observation" "" "" 15/02/2006 15/02/2006 "Tipping bucket found out of position" "Tipping bucket found out of position and may not have been registering data properly" "" "" "Crane Top" "Tipping Bucket" "Moved" "" "" 15/02/2006 15/02/2006 "Move Tipping bucket to correct position" "Install one PAR sensor to replace the two damaged sensors. Calibration coefficient of 273.2 missing from program until July 19" "" "" "Crane Top" "Tipping Bucket" "Modified" "" "" 15/02/2012 15/02/2012 "Level Tipping bucket" "" "" "" "Crane Top" "Pyranometer" "Modified" "" "" 15/02/2012 15/02/2012 "Level Pyranometers" "" "" "" "Crane Top" "Battery" "Replaced" "" "" 15/04/2008 15/04/2008 "Replace battery" "Battery replaced because it had difficulty holding a charge" "" "" "Crane Top" "Tipping Bucket" "Observation" "" "" 15/07/2010 05/08/2010 "Tipping Bucket cable broken" "August 5th, 2010 Logger disconnected between 11:30 and 13:10. The Tipping Bucket cable was found to be broken on August 5th, 2010. The cable got damaged sometime between July 16 and July 29. On August 5th the Tipping bucket cable was fixed-up. Failed" "attempt to replace the support U-bolts - Tipping bucket had to be attached with cables ties to the support bars, i.e. cables ties to attached PVC support to the metal bars of the crane's counterbalance concrete structure" "" "Crane Top" "Tipping Bucket" "Replaced" "2012-205" "06-89" 17/01/2013 17/01/2013 "Replaced Tipping bucket with new model" "January 17, 2013 Logger shutdown at 12:10 pm -Removed Hydrological Services TB4/0.01" " S/N 06-89 -Installed new Hydrological Services TB3/0.254mm 2012-205" " " "Crane Top" "T&H sensor" "Replace shield" "E4333" "" 17/01/2013 17/01/2013 "Replace radiation shield on T&H Sensor" "January 17, 2013 Logger shutdown at 12:10 pm -Replaced radiation shield on CS215 Temp&Relative Humidity Sensor" "" "" "Crane Top" "Telemetry" "Observation" "" "" 17/01/2013 17/01/2013 "Tested Raven GPRS cellular modem with a Claro SIM card, Omnidirectional antenna" "January 17, 2013 Logger shutdown at 12:10 pm -Tested Raven GPRS cellular modem with a Claro SIM card, Omnidirectional antenna - No cellular coverage with Claro" "" "" "Crane Top" "T&H sensor" "Observation" "E4333" "" 17/01/2013 17/01/2013 "T&H Sensor filter cap screen broken. Must be replaced soon." "January 17, 2013 Logger shutdown at 12:10 pm -CS215 filter cap scren in section broken. Must be replaced soon." "" "" "Crane Top" "Datalogger" "Reprogrammed" "" "" 17/01/2013 17/01/2013 "Reload Datalogger program" "Logger shutdown at 12:10 pm-Reloaded datalogger program Sherman_crane20110323kk.CR1" "" "" "Crane Top" "Datalogger" "Replaced" "X35595" "X19475" 17/02/2009 17/02/2009 "Change Logger for Calibrated one" "February 17, 2009 Calibrated Logger installed S/N: X35595 calibrated date: 14 Nov. 2008 due date: 14 Nov. 2010 Logger retirado S/N: X19475 Observations: - Charging signal on regulator intermitent - keep an eye on battery voltage - The program loaded (S" "hermanPB20090212kk.dld) does Not have ajusment for wind direction - must be corrected." "" "Crane Top" "Pyranometer" "Replaced" "61707" "47798" 17/02/2009 17/02/2009 " Change Pyranometer" "Feb. 17, 2009 Installed the program ShermanPB20090212.dld Installed Pyranometer LICOR S/N61707 Sensor Pyranometro retirado de Sherman LICOR S/N: PY47798 Performed on Feb. 17, 2009" "" "" "Crane Top" "Pyranometer" "Repaired" "61707" "" 17/02/2009 17/02/2009 "Fix Pyranometer Base" "Installed new base for Pyranometer, the previous base did not allow for pyranometer to be properly leveled. Performed on Feb.17,2009" "" "" "Crane Top" "Telemetry" "Observation" "" "" 18/05/2009 18/05/2009 "Radio Problem" "The Sherman Station stopped sending data on April 22, 2009. On May 6th, 2009 the radios at Galeta were checked - these were powered but were not communication with the Sherman radio. No green lights on CD,TX,CTS for the Master and Repeater atGaleta. Mo" "nday, May 18th 2009 -The slave radio at sherman had only a flashing red ligth. -The logger was working and the radio had enough power. -Connected the yaggi directly on to the radio and made no difference, i.e. no apprent problem with the coax cable at Sh" "erman. -The slave radio had the correct settings -The repeater at Galeta had the proper settings. -Repeater with t CD solid red and CTS flasing red -Base radio at galeta had the proper settings -Base radio CD slid red and TX solid red There is no commu" "Crane Top" "Anemometer" "Observation" "" "" 18/12/2002 18/12/2002 "Anemometer has bad propeller bearings" "" "" "" "Crane Top" "Anemometer" "Replaced" "" "" 18/12/2002 18/12/2002 "Replace Anemometer" "" "" "" "Crane Top" "Pyranometer" "Replaced" "82521" "86863" 19/06/2015 19/06/2015 "Replace Pyranometer front" "June 19, 2015 Logger shutdown at 10:30 am -Removed forward (F) pyranometer PY86863 -Installed forward (F) pyranometer PY82521 Logger power-up at 12:25 pm" "" "" "Crane Top" "Pyranometer" "Replaced" "82520" "86864" 19/06/2015 19/06/2015 "Replace Pyranometer back" "June 19, 2015 Logger shutdown at 10:30 am -Removed back (B) pyranometer PY86864 -Installed back (B) pyranometer PY82520 Logger power-up at 12:25 pm" "" "" "Crane Top" "Pyranometer" "Observation" "86864" "86864" 19/06/2016 14/07/2016 "Bad data from Jun 19 to July 13" "" "" "" "Crane Top" "" "" "" "" 19/11/2009 19/11/2009 "Annual Calibration09" "The Temp&RH sensor currently installed at Sherman (Humitter 50 YC CE) has SN:A2330042" "" "" "Crane Top" "Datalogger" "Reprogrammed" "" "" 20/02/2013 20/02/2013 "Converted to MySQL" "February 20, 2013 -At 11:05am uploaded the program Sherman_crane20130220kk.CR1 to CR1000 datalogger. -Installed C&W sim card on GPRS modem - Signal and Network LEDs solid green" "" "" "Crane Top" "PAR sensor" "Replaced" "" "" 20/04/2006 20/04/2006 "Replace PAR sensor" "" "" "" "Crane Top" "Enclosure" "Replaced" "" "" 20/04/2006 20/04/2006 "Replace Equipment shelter" "" "" "" "Crane Top" "Tipping Bucket" "Replaced" "" "" 20/06/2002 20/06/2002 "Replace Tipping bucket" "Tipping bucket moved by workers. No good data between Dec 23, 2001 and June 20, 2002. Data replaced in database by data from the ACP Gatun West site" "" "" "Crane Top" "Anemometer" "Repaired" "" "" 20/12/2006 20/12/2006 "Replace Anemometer propeller bearings" "" "" "" "Crane Top" "Anemometer" "Repaired" "" "" 22/06/1999 22/06/1999 "Repair support bar" "" "" "" "Crane Top" "PAR sensor" "Replaced" "" "" 22/06/1999 22/06/1999 "Replace both PAR sensors" "" "" "" "Crane Top" "Net Radiometer" "Discontinued" "" "" 22/06/1999 22/06/1999 "Remove Net radiometer" "" "" "" "Crane Top" "Datalogger" "Replaced" "38946" "35595" 23/03/2011 23/03/2011 "Replace Datalogger with new model" "March 23, 2011 The station was shutdown at 11:35 -Removed datalogger CR10XPB S/N35595 -Installed CR1000 S/N38946 - set to PB20 The station was powered up at 13:12" "" "" "Crane Top" "Pyranometer" "Replaced" "63943" "10373" 23/03/2011 23/03/2011 "Replace Pyranometer back" "March 23, 2011 The station was shutdown at 11:35 -Removed pyranometer PY10373 (Back pyranometer) -Installed pyranometer PY63943 - (Back pyranometer) must be removed in 03/2012 The station was powered up at 13:12" "" "" "Crane Top" "Tipping Bucket" "Leveled" "" "" 23/03/2011 23/03/2011 "Clean and level Tipping bucket" "March 23, 2011 The station was shutdown at 11:35 -Cleaned and leveled TB4 The station was powered up at 13:12" "" "" "Crane Top" "Anemometer" "Observation" "" "" 23/04/1999 22/06/1999 "Support bar broken. All data bad during this period" "Disconnected wire beginning Nov 10 @ 14:15hr" "" "" "Crane Top" "T&H sensor" "Chip Replaced" "" "" 23/06/2005 23/06/2005 "Replace sensor head of Temp/Hum sensor" "" "" "" "Crane Top" "Pyranometer" "Discontinued" "" "" 23/06/2005 23/06/2005 "Remove Pyranometer" "" "" "" "Crane Top" "PAR sensor" "Installed" "" "" 23/06/2005 23/06/2005 "Install PAR sensor" "" "" "" "Crane Top" "Anemometer" "Observation" "" "" 23/06/2005 23/06/2005 "Anemometer not spinning at low wind speeds" "" "" "" "Crane Top" "Tipping Bucket" "Observation" "" "" 23/12/2001 19/06/2002 "No Precipitation data during this period" "" "" "" "Crane Top" "Anemometer" "Reprogrammed" "" "" 25/02/2009 25/02/2009 "Correct Wind Direction" "This was done directly on the program for the station shermanpb20090212.csi - the correction was introduced on Feb. 25 - 2009. The correction done consisted on adding 30 degress to the wind direction value.The Program loaded was SHERMANPB20090212.dld" "Sergio dos Santos" "" "Crane Top" "Anemometer" "Replaced" "40007" "19852" 25/09/2013 25/09/2013 "Replace Anemometer" "September 25, 2013 Data logger shutdown at 11:46 am -Installed 05103 Anemometer SN40007 -Removed 05103 Anemometer SN19852 Data logger startup at 12:54" "" "" "Crane Top" "T&H sensor" "Replaced" "E4058" "E4333" 25/09/2013 25/09/2013 "Replaced T&RH Sensor" "September 25, 2013 Data logger shutdown at 11:46 am -Installed CS215 T&RH sensor SNE4058 -Removed CS215 T&RH SNE4333 Data logger startup at 12:54" "" "" "Crane Top" "Anemometer" "Repaired" "" "" 26/01/2000 26/01/2000 "Fix Anemometer - loose connection" "Reconnected wire. Added strain relief to avoid problem in the future" "" "" "Crane Top" "Anemometer" "Calibrated" "" "" 26/01/2000 26/01/2000 "Calibrate wind direction" "Adjust wind direction by -20 degrees" "" "" "Crane Top" "T&H sensor" "Observation" "E7220" "E7220" 26/06/2016 13/07/2016 "Bad data from June 26 to July 13" "" "" "" "Crane Top" "Anemometer" "Observation" "" "" 26/09/2002 18/12/2002 "No Anemometer data during this period" "Last known good data was on Jan 29, 2003" "" "" "Crane Top" "Anemometer" "Observation" "" "" 27/04/1998 02/06/1998 "Anemometer cable disconnected" "Cable disconnected from datalogger" "" "" "Crane Top" "Anemometer" "Repaired" "" "" 27/07/2006 27/07/2006 "Replace Anemometer propeller bearings" "" "" "" "Crane Top" "Tipping Bucket" "Replaced" "" "" 27/07/2007 27/07/2007 "Replace Tipping bucket" "Installed new wooden intrument shelter in the clearing area beside the kitchen. Shelter placed on top of metal bench because metal legs for the shelter did not arrive with the box. This leaves the shelter at about 30-40cm above the ground. Legs will be i" "nstalled at a later date." "" "Crane Top" "Datalogger" "Replaced" "" "" 27/07/2007 27/07/2007 "Replace Datalogger" "" "" "" "Crane Top" "PAR sensor" "Replaced" "" "" 27/07/2007 27/07/2007 "Replace PAR sensor" "" "" "" "Crane Top" "T&H sensor" "Replaced" "" "" 27/07/2007 27/07/2007 "Replace Temp/Hum sensor" "" "" "" "Crane Top" "Datalogger" "Reprogrammed" "" "" 27/07/2011 27/07/2011 "Correct Time stamp on data logger" "July 27, 2011 Corrected the datalogger time at 11:40 am Collected all the data until July 27, 2011 at 11:30 am" "" "" "Crane Top" "Pyranometer" "Replaced" "82521" "73904" 28/05/2014 28/05/2014 "Replace Pyranometer front" "May 28, 2014 Logger shutdwon at 12:25 -Removed pyranomters LI200S PY73904 -Installed pyranometers LI200S PY82521(F)" "" "" "Crane Top" "Pyranometer" "Replaced" "82520" "73905" 28/05/2014 28/05/2014 "Replace Pyranometer back" "May 28, 2014 Logger shutdwon at 12:25 -Removed pyranomters LI200S PY73905 and PY73904 -Installed pyranometers LI200S PY82520(B)" "" "" "Crane Top" "Tipping Bucket" "Observation" "" "" 28/07/2004 12/08/2004 "No Precipitation data during this period" "" "" "" "Crane Top" "Tipping Bucket" "Observation" "" "" 29/01/2003 06/05/2003 "No Precipitation data during this period" "" "" "" "Crane Top" "Rain Gauge" "Installed" "" "" 29/10/1997 29/10/1997 "Install Raingauge" "" "" "" "Crane Top" "T&H sensor" "Repaired" "E4333" "" 30/01/2013 30/01/2013 "Install pole for T&RH, replace T&RH cap" "January 30, 3013 -Installled a galvanized pole for the T&RH sensor -Intalled a new filter cap on the T&RH sensor" "" "" "Crane Top" "Anemometer" "Observation" "" "" 30/06/1998 01/07/1998 "Anemometer out of position" "" "" "" "Crane Top" "PAR sensor" "Installed" "" "" 31/03/1999 31/03/1999 "Install PAR sensor" "Additional PAR sensor installed. Connected to LiCor datalogger" "" "" "Crane Top" "PAR sensor" "Replaced" "" "" 31/07/2002 31/07/2002 "Replace PAR sensor" "Replaced anemometer, but wind direction not working" "" "" "Crane Top" "PAR sensor" "Observation" "" "" 31/07/2002 31/07/2002 "PAR sensor not correctly leveled" "" "" "" "Crane Top" "Pyranometer" "Installed" "" "" 31/07/2002 31/07/2002 "Install Pyranometer" "" "" ""